0~120V/1mA~30A/150W,Battery test,programmable electronic load,electronic load
Function:
CC mode
In the mode of CC, electronic load analogs as a constant load, the current won’t change as voltage when the current is within the input range
For reducing the current setup critical shock, the rise time can be set, load controls the current to rise
In the process of CC, switch to short working status directly, load controls the Max.current to
Test the short input of power and protection ability.
CV mode
In the mode of CV, electronic load analogs as a constant load, the voltage won’t change as current when the current is within the input range
For reducing the voltage shock, the rise time can be set, load controls the voltage to rise
In the process of CV, switch to short working status directly, load controls the Min.voltage to
Test the short input of power and protection ability.
CP mode
In the mode of current power, within the power input ability range, electronic load consumes a constant power, generally, analog in terms of constant current, load current is adjusted dynamically with voltage.
In the mode of CP, load consumes a constant power. When the input voltage changes, load will adjust current to maintain the consumed power.
CR mode
In the mode of constant resistance, load works in terms of CC or CV, the load current or voltage can be adjusted dynamically according to the change of input power, so that load equals to a constant resistance.
In the mode of CR, load equals to a constant resistance, load will consume the current changed as voltage
Battery measurement mode
The discharge test works in terms of CC or CR, and test automatically in same mode or different modes according to the set switch time to analog the working status of battery; in the process of lasting discharge, the battery voltage drops constantly, when load input voltage is lower than the set value, the discharge test stops automatically, and the tester can display the discharge time and the capacitance of battery.
Auto list measurement mode
List test function can realize the different loads to switch automatically based on the set time.
As for the power and discharge device, the working feature of tested product in different application can be got deeply and widely by multi parameter fixed test.
Application:Production line(cell phone charger, cell phone battery, electric vehicle battery, switching power supplier, linear power supplier), research insititutes, automotive electronics, aeronautics and astronautics,ships, solar cells fule cell, etc.
SPECIFICATIONS
Rated value | Input voltage | 0~120V | |
input current | 1mA~30A | ||
input power | 150W | ||
range | accuracy | resolution | |
acy Load accur | 0-9.999V | ±(0.1%+0.03%FS) | 1mV |
10V-99.99V | ±(0.1%+0.03%FS) | 10 mV | |
100V-120V/360V | ±(0.1%+0.03%FS) | 100mV | |
0-9.999A | ±(0.1%+0.2%FS) | 1mA | |
0-15A/30A | ±(0.2%+0.5%FS) | 10 mA | |
CV mode | 1.5V-18V/36V | ±(0.1%+0.03%FS) | 1mV |
1.5V-120V/360V | ±(0.1%+0.03%FS) | 10 mV | |
CC mode | 0-3A | ±(0.1%+0.2%FS) | 1mA |
0-15A/30A | ±(0.2%+0.5%FS) | 10mA | |
CR mode | 0.1Ω-10Ω | ±(1%+0.3%FS) | 0.001Ω |
10Ω-99Ω | ±(1%+0.3%FS) | 0.01Ω | |
100Ω-999Ω | ±(1%+0.3%FS) | 0.1Ω | |
1KΩ-4KΩ | ±(1%+0.8%FS) | 1Ω | |
CP mode | 0-10W | ±(1%+0.1%FS) | 1 mW |
10-100W | ±(1%+0.1%FS) | 1 0mW | |
100-300W | ±(1%+0.1%FS) | 0.1 W | |
Battery test functionn | Input:0.8-120V Max measurement capacity:999A/H | ||
Resolution:10 mA Timer range:1~60000sec | |||
Dynamic test mode | Range of Frequency 0.1Hz-1KHz | ||
Llist test mode | Rated Voltage, Rated Current, Rated Power | ||
Rated Riesistance, SHORT, OPEN | |||
Protection mode | Over-voltage,over-current,over-power,over-temperature,opposite polarity | ||
Power requirement | 198-242VAC 99V-121VAC 47.5-63Hz |
0~120V/1mA~30A/150W,Battery test,programmable electronic load,electronic load