Thermocouple Calibrator,precision calibrator,handheld calibrator,0.05% Accuracy
Features and Benefits
Output of DC mV and simulation of thermocouple output. Voltage, DC mV and thermocouple measurement. Automatic and manual cold end temperature compensation for TC.Manual stepping, automatic stepping, 0~100% phase step and slope outputSummary of Source and Measure Functions
Function | Measure | Source |
DC V | 0~30 V | Not available |
DC mV | 0~100 mV | 0~100 mV |
Thermocouple | E,J,K,T,B,R,S,N | E,J,K,T,B,R,S,N |
Others | Stepping output, ramp, phase step output, user-defined range |
Specifications
Specifications are based on a one year calibration cycle and apply from +18°C to +28 °C unless stated otherwise. All specifications assume a 10 minute warmup period.
1,DC Voltage Measurement
Range | Maximum measurement range | Resolution | Accuracy (% of reading + Counts) | |
ETX-1814 | ETX-2014 | |||
30V | 0V~31V | 0.001V | 0.05+2 | 0.02+2 |
100mV | -15mV~125mV | 0.01mV | 0.05+2 | 0.02+2 |
-10°C~18°C,+28°C~55°C temperature coefficient,±0.005%FS/°C. Input resistance: >1MΩ. |
2,Thermocouple
Graduation | Range | Resolution | Accuracy (Ω) | |
ETX-1814 | ETX-2014 | |||
J | -200°C~0°C 0°C~1200°C | 0.1°C | 1.5°C 1.0°C | 1.0°C 0.7°C |
K | -200°C~0°C 0°C~1370°C | 0.1°C | 1.8°C 1.2°C | 1.2°C 0.8°C |
T | -200°C~0°C 0°C~400°C | 0.1°C | 1.8°C 1.2°C | 1.2°C 0.8°C |
E | -200°C~0°C 0°C~950°C | 0.1°C | 1.5°C 1.0°C | 0.9°C 0.7°C |
R | -20°C~0°C 0°C~500°C 500°C~1750°C | 1°C | 4°C 2.5°C 2°C | 2.5°C 1.8°C 1.4°C |
S | -20°C~0°C 0°C~500°C 500°C~1750°C | 1°C | 4°C 2.5°C 2°C | 2.5°C 1.8°C 1.5°C |
B | 600°C~800°C 800°C~1000°C 1000°C~1800°C | 1°C | 3.5°C 2.5°C 2°C | 2.2°C 1.8°C 1.4°C |
N | -200°C~0°C 0°C~1300°C | 0.1°C | 2.0°C 1.2°C | 1.5°C 0.9°C |
Errors of cold-junction compensation are not included in the table. Accuracy of cold-junction compensation: 1.5°C |